Products in stock
Stock list updated: 17 Nov 2026, 03:00. Quantities are indicative and change daily. Please enquire to confirm availability.
Showing 301–350 of 446 items
| Image | Stock code | Part number | Description | Manufacturer | Qty | Datasheet |
|---|---|---|---|---|---|---|
| 15M4175-X | NR2-25-1.0 | THERMAL OVERLOAD PROTECTION RELAY 0.63-1A 0.37KW NR2-25-1.0DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 39 | ||
| 15M4177-X | NR2-25-10 | THERMAL OVERLOAD PROTECTION RELAY 7-10A 4KW NR2-25-10DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 29 | ||
| 15M4178-X | NR2-25-13 | THERMAL OVERLOAD PROTECTION RELAY 9-13A 5.5KW NR2-25-13DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 41 | ||
| 15M4180-X | NR2-25-2.5 | THERMAL OVERLOAD PROTECTION RELAY 1.6 - 2.5A 0.75KW NR2-25-2.5DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 84 | ||
| 15M4181-X | NR2-25-25 | THERMAL OVERLOAD PROTECTION RELAY 17-25A 11KW NR2-25-25DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 42 | ||
| 15M4182-X | NR2-25-2.5-4A | THERMAL OVERLOAD PROTECTION RELAY 2.5-4.0A 1.5KW NR2-25-2.5-4ADetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 1 | ||
| 15M4183-X | NR2-25-4-6A | THERMAL OVERLOAD PROTECTION RELAY 4.0-6.0A 2.2KW NR2-25-4-6ADetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 13 | ||
| 15M4184-X | NR2-25-5.5-8A | THERMAL OVERLOAD PROTECTION RELAY 5.5-8.0A 3KW NR2-25-5.5-8ADetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 96 | ||
| 15M4186-X | NR2-36-32 | THERMAL OVERLOAD PROTECTION RELAY 23-32A 15KW NR2-36-32DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 18 | ||
| 15M4187-X | NR2-36-36 | THERMAL OVERLOAD PROTECTION RELAY 28-36A 18.5KW NR2-36-36DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 4 | ||
| 15M4188-X | NR2-630-630A | THERMAL OVERLOAD PROTECTION RELAY 400-630A NR2-630-630ADetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 1 | ||
| 15M4189-X | NR2-93 | THERMAL OVERLOAD PROTECTION RELAY NR2-93 NR2-93DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 3 | ||
| 15M4190-X | NR2-93-40 | THERMAL OVERLOAD PROTECTION RELAY 30-40A 18.5KW NR2-93-40DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 2 | ||
| 15M4192-X | NR2-93 48-65A | THERMAL OVERLOAD PROTECTION RELAY 48-65A 30KW 268148 NR2-93 48-65ADetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 1 | ||
| 15M4193-X | NR2-93 55-70A | THERMAL OVERLOAD PROTECTION RELAY 55-70A 268120 NR2-93 55-70ADetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 11 | ||
| 15M4195-X | NR2-93-93 | THERMAL OVERLOAD PROTECTION RELAY 80-93A 45KW NR2-93-93DetailsADJUSTABLE THERMAL OVERLOAD PROTECTION RELAY. PLUGS DIRECTLY UNDER CONTACTOR. WITH STOP / TEST AND RESET BUTTONS. |
CHINT | 3 | ||
| 15M4196-X | NS2-X25-0.63-1.0A | MANUAL MOTOR STARTER 0.63-1A NS2-X25-0.63-1.0ADetailsALTERNATING CURRENT MOTOR STARTER |
CHINT | 19 | ||
| 15M4197-X | NS2-25-0.63A | MANUAL MOTOR STARTER 0.4-0.63A- NS2-25-0.63A | CHINT | 5 | ||
| 15M4199-X | NS2-25-18 | MANUAL MOTOR STARTER 13 -18A NS2-25-18 | CHINT | 13 | ||
| 15M4202-X | NS2-25-25 | MANUAL MOTOR STARTER 20-25A NS2-25-25 | CHINT | 9 | ||
| 15M4204-X | NS2-25-4.0-6.3A | MANUAL MOTOR STARTER 4-6.3A 2.2KW 100KA NS2-25-4.0-6.3ADetailsMANUAL MOTOR STARTER / MOTOR CIRCUIT BREAKER 4-6.3A |
CHINT | 21 | ||
| 15M4205-X | NS2-80B-40 | MANUAL MOTOR STARTER 25-40A NS2-80B-40 | CHINT | 4 | ||
| 15M4206-X | NS2-80B-63 | MANUAL MOTOR STARTER 40-63A NS2-80B-63 | CHINT | 9 | ||
| 15M4207-X | NS2-80B-80 | MANUAL MOTOR STARTER 56-80A NS2-80B-80 | CHINT | 8 | ||
| 15M4208-X | NS2-AE11 | FRONT AUXILLARY FOR MMS 1NO + 1NC NS2-AE11DetailsAUXILIARY CONTACT BLOCK FOR MANUAL MOTOR STARTER |
CHINT | 1 | ||
| 15M4210-X | NS2-AU11-80 | AUXILIARY CONTACT FOR NS2-80B MMS NS2-AU11-80DetailsAUXILIARY CONTACT BLOCK FOR MANUAL MOTOR STARTER, 1NO + 1NC |
CHINT | 4 | ||
| 15M4211-X | NS2-MC | WATERPROOF ENCLOSURE IP65 FOR NS2-25 NS2-MCDetailsENCLOSURE TO FIT NS2-25 NOT SUPPLIED |
CHINT | 33 | ||
| 15M4212-X | NS2-MC01 | WATERPROOF ENCLOSURE + E/ STOP IP65 FOR NS2-25 NS2-MC01DetailsENCLOSURE WITH EMERGENCY STOP TO FIT NS2-25 NOT SUPPLIED |
CHINT | 41 | ||
| 15M4213-X | NS2-UV380 | UNDER VOLTAGE RELEASE 380-400V NS2-UV380 | CHINT | 3 | ||
| 15M4214-X | NTE8-B-1S-10S-AC230V | DELAY ON TIMER RELAY D/RAIL 1s- 10SEC 230VAC NTE8-B-1S-10S-AC230VDetailsMINI DIN RAIL DELAY TIMER RELAY ON 1SEC TO 10SEC 230VAC |
CHINT | 2 | ||
| 15M4215-X | NTE8-B-12S-120S-AC230V | DELAY ON TIMER RELAY D/RAIL 12S- 120SEC 230VAC NTE8-B-12S-120S-AC230VDetailsDIN RAIL MOUNT TIMER / TIMING RELAY |
CHINT | 1 | ||
| 15M4217-X | SR2-B-200V-250V | RC SURGE SUPPRESSOR / FILTER 200-250VAC 40-95A SR2-B-200V-250VDetailsR+C CONTACTOR COIL SPIKE / BACK-EMF, SPARK SUPPRESSOR / FILTER. |
CHINT | 25 | ||
| 15M4394 | NB1-DC-C20 | MINI CIRCUIT BREAKER 10KA 125VDC 2P 20A NB1-DC-C20DetailsDC DIN RAIL MOUNT MINIATURE CIRCUIT BREAKER |
CHINT | 5 | – | |
| 15M5308 | OUVR-2-40A-1P+N / | OVER / UNDER VOLTAGE RELAY 230V 40A OUVR-2-40A-1P+N /DetailsDIN RAIL MOUNT OVER AND UNDER VOLTAGE PROTECTION RELAY. OV=275VAC, UV=161VAC |
CHINT | 7 | ||
| 15M5311 | OUVR-1-40A-1P+N | OVER / UNDER VOLTAGE RELAY 230V 40A OUVR-1-40A-1P+NDetailsDIN RAIL MOUNT OVER AND UNDER VOLTAGE PROTECTION RELAY. OV=270VAC, UV=170VAC |
CHINT | 3 | ||
| 15M5318 | OUVR-1-80A-1P+N | OVER / UNDER VOLTAGE RELAY 230V 40A OUVR-1-80A-1P+NDetailsDIN RAIL MOUNT OVER AND UNDER VOLTAGE PROTECTION RELAY. OV=270VAC, UV=170VAC |
CHINT | 2 | ||
| 15M6278 | YBLX-K1/411 | LIMIT SWITCH WITH ROLLER WHEEL YBLX-K1/411DetailsTRAVEL LIMIT SWITCH |
CHINT | 17 | – | |
| 15M6571-X | F8-11 | AUXILIARY CONTACTS FOR CONTACTOR 1-NO + 1-NC 10A 690V F8-11DetailsFRONT MOUNTED AUXILIARY CONTACT FOR NC8 1 |
CHINT | 2 | ||
| 15M7609-X | NM1-250S-25K-3P-3300-225A | MOULDED CASE ISOLATOR 3POLE 225A 25KA NM1-250S-25K-3P-3300-225ADetails3 POLE MOULDED CASE LOAD BREAKER ADJUSTABLE |
CHINT | 10 | ||
| 15M7792-X | NM1-225H-3300 | MOULDED CASE CIRCUIT BREAKER 3POLE 225A 50KA NM1-225H-3300Details3 POLE MOULDED CASE CIRCUIT BREAKER ADJUSTABLE |
CHINT | 2 | ||
| 15M7793 | NM1-100S/3300 16A | MOULDED CASE CIRCUIT BREAKER 3POLE 16A 25KA NM1-100S/3300 16ADetails3 POLE MOULDED CASE CIRCUIT BREAKER ADJUSTABLE |
CHINT | 1 | ||
| 15M7797-X | RH31 | EXTENDED ROTARY HANDLE RH31 | CHINT | 2 | – | |
| 15M7798-X | NR2-93 | MOUNTING BASE FOR NR2-93 RELAY NR2-93 | CHINT | 4 | – | |
| 15M7799-X | NM1-125/CS1 | VARIABLE DEPTH HANDLE FOR NM1-125 NM1-125/CS1 | CHINT | 12 | – | |
| 15M7803-X | LX1FG400 | COIL FOR CONTACTORS 415VAC NC2-185 LX1FG400 | CHINT | 28 | – | |
| 15M7804-X | CJX2-40-95A/525V | COIL FOR CJX2-40/95A 525V 50Hz CJX2-40-95A/525VDetailsREPLACEMENT COIL FOR CONTACTORS |
CHINT | 8 | – | |
| 15M7805-X | CJX2-40-95A/525V-H | ENCLOSED COIL FOR NC1-40/95A 525V 50Hz CJX2-40-95A/525V-HDetailsHOUSED REPLACEMENT COIL FOR CONTACTORS |
CHINT | 13 | – | |
| 15M7806-X | FF400 | COIL FOR CONTACTORS 415VAC NC2-115-150 FF400 | CHINT | 60 | – | |
| 15M7808-X | FF240 | COIL FOR CONTACTORS 240VAC NC2-115-150 FF240 | CHINT | 7 | – | |
| 15M7810-X | CJX2-40-95A/415V-H | ENCLOSED COIL FOR CJX2-40/95A 415V 50Hz CJX2-40-95A/415V-HDetailsHOUSED REPLACEMENT COIL FOR CONTACTORS, CONTACTOR-COIL, |
CHINT | 52 | – |
